The prices comply with the recommended retail price of the respective manufacturers.

to display your individual prices.

Due to the persistently difficult global delivery situation, we can no longer show you reliable stock levels online. We regularly adjust our delivery times to give you an indication of their duration. Please also use the opportunity to make an offer. Offers receive calculated delivery dates and can be converted into an order at any time. You will be informed of the delivery date after receipt of your order. If in doubt, please inquire in advance.

Modular Metering Device PSG1

Artikel-Nr.: PSG1
Segmentverteiler PSG1 Grundausführung
Segmentverteiler PSG1 Kolbendetektor
Segmentverteiler PSG1 Optischer Zyklenanzeiger
Segmentverteiler PSG1 Optischer Zyklenanzeiger mit gehäuse
Beispielhafte Darstellung, Produkt kann abweichen.
Price only for registered members
  • PSG1
  • Please inquire the required version.
  • 1
  • 1
  • 500
Function: PSG1 lubricant distributor Outlets: 6 - 20 Lubricant: Grease up to NLGI 2, oil...more
Modular Metering Device PSG1
  • Function: PSG1 lubricant distributor
  • Outlets: 6 - 20
  • Lubricant: Grease up to NLGI 2, oil with a viscosity of at least 12 mm²/s
  • Dosage quantity: 0.05 - 0.25 cm³ per cycle and outlet
  • Operating temperature: -15 to +110°C
  • Operating pressure: max. 200 bar
  • Base plate material: aluminum alloy
  • Material segments: steel, galvanized
  • Connections inlet/outlet: G 1/8
  • Dimensions: min. 90 x 55 x 41 mm; max. 244 x 55 x 41 mm
  • Installation position in machines without vibration: any
  • Installation position in machines with vibration: the piston should be aligned at a 90° angle to the direction of movement of the machine
Available downloads:
PSG1 lubricant distributor in segment design for automatic progressive lubrication systems The...

PSG1 lubricant distributor in segment design for automatic progressive lubrication systems

The PSG1 is a progressive lubricant distributor that consists of a base plate and metering disks. The metering discs can be dismantled without detaching the lines as all inlets and outlets are attached to the common base plate. By loosening the internal adjusting screw, two opposite outlets can be combined internally. Up to three outlets can be combined externally using a connector (crossporting). At least three dosing segments (disks) are required per distributor.

Areas of application

  • Forming machines (presses)
  • Tunnel boring machines
  • Paper machines
  • General Engineering

Advantages

  • Easy to service thanks to outlets located in the base plate, pipes do not have to be dismantled for maintenance work, number of outlets 1 to 20
  • Flexible thanks to interchangeable dosing segments
  • Can be expanded by adding flow limiters, flow regulators, gear controls and directional solenoid valves
  • Efficient due to low pressure loss
  • Can be monitored by piston detectors or optical cycle indicators
  • Customizable by combining outlets internally and externally
  • 3 sizes for the range up to 0.8; 2.5 and 6 l/min
  • Increased functional reliability thanks to standard equipment with a check valve (PSG2 and PSG3)
  • Increased dosing accuracy by placing the integrated check valves directly after the dosing piston (PSG2 and PSG3)
  • Increased corrosion resistance thanks to special versions with anodized base plate and chemically nickel-plated segments (basic version PSG2 and PSG3)

Product description

Depending on the version, the SKF segment distributors from the PSG product series (progressive distributors) are designed for an inlet volume flow of up to 0.8; 2.5 or 6 l/min can be used. The inlet and all outlets of the distributor are located in a common base plate. The dosing segments are attached to the base plate and can be replaced without loosening pipes. The volume flow supplied via a pipeline is distributed forcibly and in a predetermined ratio to the outlets, i.e. to the lubrication points or to downstream progressive distributors. Pistons working in series meter the lubricant into two opposite outlets and control the function of the neighboring piston. The function of the segment distributor can be controlled by monitoring any piston (with a cycle indicator or piston detector) or the inlet volume flow (with gear control only for PSG2 and PSG3). The check valves installed as standard (only on PSG2 and PSG3) offer a high level of functional reliability at high or different back pressures. Likewise, precise allocation and secure blocking behavior are achieved even with internal and external aggregation.

Blind segment

Blind and functional segments can be varied as desired within the size. At least 3 functional segments are required per distributor. If blind segments are installed, two lubricant outlets in the base plate (under the blind segment) must necessarily be closed. If 2 blind segments are arranged next to each other or if blind segments are used as the start or end segment, an increased pressure loss must be expected.

Monitoring

All standard segments can be directly monitored or retrofitted with a piston detector. However, if the piston movement is to be recorded by a cycle indicator (optical stroke control) or with a proximity switch, the segments provided for this purpose must be used.

Attachments

The modular structure of the segment distributor is particularly evident in the range of mounting options. Depending on the size, it can be equipped with the following attachments:

  • Quantity limiter
  • Flow regulator
  • 4/2-way solenoid valve
  • 2/2-way solenoid valve

If the inlet volume flow is to be monitored not only visually but also electrically, an upstream gear flow control can be used.